The feature to create the insection data specific for the flow surface is loaded. Easy settings, and capable of inspecting solder amount, lead condition and bridge between lands.
PCBA flipping process is skipped because the camera is incorporated underneath the machine. In addition, speed-up and space-saving are achieved.
The inspection data of whole PCBA is created by clicking the land area after inserting a raw PCB.
※ Also, capable of parts inspection same as 300 series.
The high-temperature PCBA, which is right after soldering, can be conveyed without cooling-down period by adopting the metal conveyer.
*Please see the table by scrolling horizontally.
Inspecting PCBA | M-size | ○ |
---|---|---|
L-size | - | |
Size | 100m (W) x 80mm (D) to 330mm (W) x 250mm (D) |
|
Thickness of PCBA | 0.5~2.0mm | |
PCBA maximum mass | 2kg | |
PCBA height limit (clearance) | Top surface | 75mm |
Bottom surface | 25mm | |
Resolution | 18.7μm/pixel | |
Minimum inspection component size (JIS) | 0603 | |
Inspection speed | 5,000mm2/s | |
Main inspection item | Component inspection | Missing part, wrong part, displacement, part number, shape and dimension |
Solder inspection | Excess, insufficient, unsoldered, bridge | |
Imaging range | 38.3mm×20.3mm | |
Depth of field (according to the company regulation) |
10mm | |
Repeatability of positioning | ±50μm | |
Camera | 2M Pixel | |
Lighting | RGB + warm white LED | |
Structure of imaging system | Object side telecentric optical system | |
Flow direction of PCBA | Left ← Right / Left → Right (selectable at the time of shipment) | |
Conveyance method | Metal chain | |
PCBA clamping unit | Air clamp | |
Width adjustment for transferring conveyor | Automatic | |
Height of conveyance unit | 920±50mm | |
Reference position for PCBA width |
Front | |
Monitor | Display with 21.5 inch touch panel | |
PC | OS | Windows 10 Pro 64bit Japanese / English (language is selectable at the time of shipment) |
Memory | 8GB | |
Interface between equipments | Conformance to SMEMA standard | |
Environment conditions for operation | 10 to 35℃ / 30 to 80%RH (no condensation allowed) | |
Environment conditions for storage | -10 to 60℃ / 30 to 80%RH (no condensation allowed) | |
Power supply | AC100 to 240V (single phase) | |
Air supplied | Pressure: 0.5 Mpa Consumption: 5Nℓ/min |
|
Dimensions of main unit (excluding protruding portion) | W620×D758×H1,294mm | |
Weight (excluding PC) | 180kg |